Temperature Meter MP200G

เครื่องวัดความดันลม, ความเร็วลม, ปริมาตรลม และอุณหภูมิ รุ่น MP200G แบรนด์ KIMO

Pressure, Air Velocity, Air Flow, Temperature

 

* ต้องซื้อ pitot tube เพิ่ม เพื่อวัดความเร็วลม

 Functions :

  • Pressure, Velocity, Airflow, Temperature, current/voltage, Air quality (CO/temperature), Datalogger.

 Connection

  • Interchangeable measurement modules (current/voltage, thermocouple, pressure), 
  • Wireless connection Intrument/Computer, 
  • Smart-Plus system, probes automatically recognized when connected to the instrument.

 MANOMETER

Pressure

  • MP200 P : Pressure module 0-500 Pa • Resolution 0.1 Pa
  • MP200 M : Pressure module 0-2500 Pa • Resolution 1 Pa
  • MP200 G : Pressure module 0-10,000 Pa • Resolution 1 Pa
  • MP200 H : Pressure module 0-500 mbar • Resolution 1 mbar
  • MP200 HP : Pressure module 0-2000 mbar • Resolution 1 mbar

 

Velocity

  • Pitot : 2 to 100 m/s • Resolution 0,1 m/s
  • Debimo blades : 4 to 100 m/s • Resolution 0,1 m/s

Airflow

  • Pitot : 0 to 99,999 m³/h • Resolution 1 m³/h
  • Debimo blades : 0 to 99,999 m³/h • Resolution 1 m³/h

TEMPERATURE

  • Thermocouple K : -200 to +1300°C • Resolution 0,1°C
  • Thermocouple J : -100 to +750°C • Resolution 0,1°C
  • Thermocouple T : -200 to +400°C • Resolution 0,1°C

AIR QUALITY

  • CO / temperature probe
  • CO : from 0 to 1000 ppm • Resolution 0,1 ppm from 0 to 100 ppm, 1 ppm beyond
  • Temperature : from -20°C to +80°C • Resolution 0,1 °C

CURRENT / VOLTAGE

  • 2,5 V • Resolution 0,001V
  • from 0 to 0 V • Resolution 0,01V
  • from 4/20 mA • Resolution 0,01mA

 MICRO-MANOMETER

Pressure : Automatic (MP200P) or manual self calibration (MP200 M, MP200 G), select units, pressure integration (0 to 9), point / point average, automatic point / point average, automatic average, hold, min/max values, standard deviation, storage.

Velocity : select Pitot tube or Debimo or coefficient for others sensing elements, select duct, select units, point / point average, automatic point / point average, automatic average, temperature balancing (manual and automatic), manual air pressure balancing, K2 factor, hold, min/max values, standard deviation, storage.

 THERMOCOUPLE THERMOMETER

Select units, select thermocouple type, Delta T, hold, min/max values, storage.

 CURRENT / VOLTAGE

Adjustable scales, hold, min/max values, storage.

 SONDE CO / TEMPERATURE

Audible alarm (2 thresholds), hold, min/max values, storage

 Measuring units

  • Pressure : Pa, mmH2O, mbar, hPa, In wg, mmHg, DaPa
  • Velocity : m/s, fpm, Km/h, mph
  • Airflow : m³/h, cfm, l/s, m³/s
  • Temperature : °C, °F
  • Current/voltage : V, mA
  • CO/temperature : ppm, °C or °F